How Dangerous Is Being a Lineman? Death and Injury Rates Explained

electrical power-line installers and repairers, BLS CFOI

Deaths in 2024

21

against 3.3 for all workers

Fatal injury rate, 2024

13.8 per 100,000 FTE

margin of error 3.44 — not a trend

2023 rate

18.4 per 100,000 FTE

53 deaths, same census

Electricians, same year

5.3 per 100,000 FTE

Being a lineman carried a fatal injury rate of 13.8 per 100,000 full-time-equivalent workers in 2024, against 3.3 for all workers.

That year BLS's Census of Fatal Occupational Injuries recorded 21 fatal work injuries among electrical power-line installers and repairers, the occupation that covers line work.

This page states the figures once and plainly: what the census recorded, what the rate measures, which causes were published, and the OSHA rules the trade works under.

How many linemen die each year?

In 2024, 21 linemen died on the job: the Census of Fatal Occupational Injuries recorded 21 fatal work injuries in the line-work occupation, and a fatal work injury rate of 13.8 per 100,000 full-time-equivalent workers.

The all-worker rate that year was 3.3.

BLS's fatality numbers for this trade cover the occupation electrical power-line installers and repairers, federal occupation code 49-9051.

In May 2025 that occupation employed 131,070 people, by BLS's Occupational Employment and Wage Statistics survey.

One year is a snapshot, not a series.

BLS also publishes hours-based rates, and those put the occupation at 18.4 per 100,000 in 2023 and 13.8 in 2024, with a margin of error of 3.44 on the 2023 figure and 2.59 on the 2024 figure.

Twenty-one deaths is a small count and the rate moves around it.

The next section takes up what that does and does not tell you.

One scope note: telecommunications line installers and repairers (SOC 49-9052) are a separate occupation in the same data, covering telecommunications line work rather than power line work.

The 2024 census recorded 15 deaths among them, a rate of 11.5 per 100,000.

If your question was really about telecom line work, those are your numbers.

The full picture of the trade (employers, apprenticeship, pay) is in the lineman career guide.

Browse lineman jobs

What the fatality rate means

The number to watch is not the count.

It is the rate per 100,000 full-time-equivalent workers, which is what lets an occupation of this size be compared with the whole economy: the all-worker rate in 2024 was 3.3, and power-line installers came in at 13.8.

With 21 deaths in the year, single-year rates are statistically jumpy.

BLS says so itself by publishing a margin of error alongside each figure: 3.44 around the 2023 rate and 2.59 around the 2024 rate.

The drop from 18.4 to 13.8 between the two years sits inside those bands, which means the data does not establish that the rate fell, and it equally does not establish a rise before it.

Two years of data cannot produce a trend.

Two definitional points keep the figure honest.

First, the denominator is full-time-equivalent workers, not headcount: the rate is normalized on hours actually worked.

Second, the deaths come from one BLS program (the census) while the occupation's employment figure, 131,070 in May 2025, comes from a different survey (OEWS).

Both are reported here exactly as BLS publishes them; this page does not divide one by the other.

Why there is no injury-rate number on this page

Everything above is fatality data. BLS tracks nonfatal injuries through a separate survey, and the research behind this page did not confirm a published nonfatal injury rate for power-line installers, so none is quoted here. BLS's Survey of Occupational Injuries and Illnesses is the place to look for that figure.

Causes: what BLS published on electrical exposure, falls and vehicles

BLS codes each recorded death by event, and for 2024 it published exactly one category for this occupation: 13 of the 21 deaths were classified as exposure to harmful substances or environments, the event category that includes electrical exposure.

The other event categories for power-line installers were not published; where the census table shows a dash, the count is suppressed, not zero.

So the published data for 2024 sizes the exposure category and nothing else.

The heading names three hazards because they follow from the work itself.

Electrical exposure sits inside that category: the occupation's work includes installing and repairing power lines and working on or with exposed energized lines (the exact condition OSHA's rules for the trade are written for), and its task list includes opening switches or attaching grounding devices to remove hazards from fallen lines.

Falls and vehicles are the other two.

The occupation's duty list has workers climbing poles and towers or working from truck-mounted buckets, and its tasks include driving vehicles with tools and materials to job sites.

But the census did not publish fall or transportation counts for this occupation in 2024, so nothing on this page puts a number on either: the suppression is the finding.

On falls, OSHA's rules for the trade do set a fall-protection requirement for climbers, covered in the next section.

How the trade controls risk

Two OSHA regimes cover the trade: 29 CFR 1910.269 for the operation and maintenance of electric power generation, transmission and distribution installations, and 29 CFR 1926 Subpart V for construction — new erection plus alteration, conversion and improvement of transmission and distribution lines and equipment.

Under OSHA's own text, an employer complying with 1910.269 is considered compliant with the Subpart V provisions that do not reference other subparts.

The keystone concept is the qualified employee: a training-defined status, not a license.

Only qualified employees may work on or with exposed energized lines, or in areas with unguarded, uninsulated energized parts at 50 volts or more.

OSHA defines qualified through knowledge of the equipment involved and its associated hazards, and the required training covers distinguishing exposed live parts, determining nominal voltage, knowing and maintaining minimum approach distances, using special precautionary techniques, PPE and insulated tools, and recognizing and controlling electrical hazards.

Employers must verify it through supervision and at least annual inspections, and each employee must demonstrate proficiency before training counts as complete.

The training also covers emergency procedures such as pole-top and manhole rescue.

Around that sit specific requirements: a job briefing before each job covering hazards, work procedures, special precautions, energy-source controls and PPE; at least two employees present for installation, removal or repair of lines energized above 600 volts, with narrow exceptions such as routine switching and emergency repairs to safeguard the public; and fall protection for qualified employees climbing or changing location on poles and towers, required since April 1, 2015 unless the employer can show it is infeasible or poses a greater hazard.

Trainees and unqualified employees must use it any time they are above 4 feet.

The minimum approach distance (OSHA defines it as the closest distance an employee may approach an energized or a grounded object) is established by the employer at no less than the values computed from OSHA's tables.

An employee may go inside that distance only when insulated from the energized part, when the part is insulated from the employee, or when the employee is insulated from any other conductive object, as in live-line barehand work.

This page deliberately does not publish any distance: the tables live in the regulation, and the employer's program applies them.

Two more, briefly.

Arc flash: where employees are exposed to arcs, the employer must estimate the incident heat energy and provide arc-rated clothing and PPE rated at or above that estimate whenever it exceeds 2.0 cal/cm², a requirement effective April 1, 2015.

Deenergizing and grounding: lines worked as deenergized must be deenergized and grounded under the standard's conditions, with temporary grounds placed to prevent hazardous differences in electrical potential: the equipotential zone.

Apprenticeship programs layer their own gates on top.

The Northwest Line Construction Industry JATC's registered standards, for example, require JATC approval, supportive progress reports, foreman and journeyman recommendation, hot-stick training and 750 to 1,000 hours of cold distribution work before an apprentice works above 600 volts, with minimum energized-hours thresholds before the later steps.

That progression is covered in the line apprenticeship guide.

This describes rules, not procedure

Everything above summarizes what OSHA's standards (29 CFR 1910.269 and 29 CFR 1926 Subpart V) require of employers, plus one JATC's registered standards. It is not safety instruction and not a substitute for either document: the regulation itself and the employer's own program govern what happens on a job site.

Is it getting safer?

No, the data does not show line work getting safer: two years of figures cannot say either way.

The rate was 18.4 per 100,000 in 2023 and 13.8 in 2024, with margins of error of 3.44 and 2.59.

The movement sits inside the band, so neither getting safer nor getting more dangerous survives contact with the numbers.

Anyone quoting a single year as proof of either direction is over-reading the data.

What is on the record is when specific written requirements took effect.

OSHA's fall-protection requirement for qualified climbers took effect April 1, 2015, and the arc-rated clothing threshold took effect the same date.

Whether those changes (or anything else) moved the fatality rate is a question the two years of figures above cannot answer.

BLS's census tables (the 2023 and 2024 files are both published) are the place to check for a real series.

The figures here are the trade's career reality, stated once: 21 deaths and a rate of 13.8 in 2024, against 3.3 for all workers and 5.3 for electricians in the same data.

The rules summarized in the previous section exist because the exposure is real; the numbers are the measure of it.

If you are weighing the trade against that reality, the lineman career guide covers the whole picture, and browse lineman jobs shows what utilities and contractors are hiring for now.

This page is career information, not safety, code or legal advice. The fatality figures come from BLS's Census of Fatal Occupational Injuries; the work rules summarized here are OSHA's (29 CFR 1910.269 and 29 CFR 1926 Subpart V). Read the regulation and your employer's own program for the requirements that govern a specific job.

Frequently Asked Questions

Is being a lineman more dangerous than being an electrician?

Yes, in BLS's 2024 fatal-injury data: power-line installers recorded 13.8 deaths per 100,000 full-time-equivalent workers against 5.3 for electricians (21 line-worker deaths and 53 electrician deaths).

Both sit above the 3.3 all-worker rate.

The comparison holds for fatalities only, because both figures come from the same census measuring the same thing; this page does not compare nonfatal injury rates, which come from a different BLS survey.

Do linemen work on live power lines?

Yes, working on or with exposed energized lines is part of the trade, which is why OSHA's 1910.269 regulates it in detail.

Only qualified employees, a training-defined status, may work on or with exposed energized lines, or in areas with unguarded, uninsulated energized parts at 50 volts or more; at least two employees must be present for installation, removal or repair of lines energized above 600 volts, with narrow exceptions; and employers must establish minimum approach distances at no less than the values computed from OSHA's tables.

How does line work compare with other dangerous jobs?

In the same 2024 census, the fatal injury rates per 100,000 full-time-equivalent workers were: logging workers 110.4, roofers 48.7, electrical power-line installers 13.8, telecommunications line installers 11.5, electricians 5.3, and all workers 3.3.

Same source, same year, same unit: the numbers are directly comparable, and they put line work well above the all-worker rate without placing it at the top of the table.